Skip to main content Skip to navigation

120/220CP Poly Sprayers

  • Durable high-density translucent polyethylene construction
  • Has funnel top for easy filling
  • Built-in 10˝ polypropylene air pump allows good working pressure to be obtained within moments
  • Adjustable spray nozzles give a complete range of spray patterns
  • Locking trigger for continuous spraying

Description:

The No. 120CP and No. 220CP Poly Sprayers can be used with all Nu-Calgon coil cleaners such as CalClean®, Special HD CalClean®, Alka-Brite® Plus, Nu-Brite®, Evap Pow’r®-C, Cal-Brite® and Cal-Shield®. These sprayers can be used for spraying solutions on air conditioning cooling coils, air-cooled condensers, finned heating coils, refrigeration case or cooler coils, permanent air filters and other greasy, dirty surfaces.

Packaging Size Part Number Additional Info
1 gallon 120CP 4770-20
2 gallon 220CP 4771-30

Directions:

  1. Inspect sprayer, and insure the hose is securely attached to the tank and to the shut-off handle.
  2. Remove the pump from the tank by turning counter clockwise.
  3. To minimize foaming when preparing a cleaning solution, add water to the tank before adding the cleaning solution. Fill tank to fill line on side of tank.
  4. Close tank by inserting pump assembly through opening. Turn cap right (clockwise) until pump is sealed tightly into the tank (hand-tighten only).
  5. Pump plunger to compress air and create pressure in tank. Twenty strokes of plunger provides a good working pressure. As pressure drops during use, recharge with 20 or more pump strokes. More strokes will be needed if the tank is not full, or as the sprayer is used and the pressure drops.
  6. The nozzle tip may be adjusted to provide a single-needle stream (tip screwed all the way out) or a fine mist (tip screwed all the way in). Spraying time will vary from about 5 minutes with the needle spray to about 12-15 minutes with the fine mist. The needle spray should be used on finned coils to reach the third and fourth banks better. The mist is better for cleaning permanent filters.
  7. Allow the cleaning solution to remain in contact with the dirty surface for about 15 minutes, then flush with water from a hose. If a hose is not available, fill the sprayer with water and flush using a course spray.

Product Information:

Literature Downloads

Download the product bulletin and other relevant literature here.

Labels

Download a low resolution file of the product label here.

Product Safety

RTK Information

2611 Schuetz Rd. St. Louis, MO 63043
  • Telephone: 800.554.5499
  • Email: info@nucalgon.com
  • Hours: Mon–Fri: 8:00am - 5:00pm (Central Time)

We'd love to hear from you.

We'd love to hear from you.

Click the box to submit